ABOUT THE GAS HEATING / ELECTRIC
COOLING UNIT
Thisgasheatingunitwithelectriccoolinghasbeendesigned
and built to provide many years of safe and dependable comfort,
providingitisproperlyinstalledandmaintained.Withregular
maintenance, this unit will operate satisfactorily year after year.
Abuse,improperuse,and/orimpropermaintenancecanshorten
thelifeoftheapplianceandcreateunsafehazards.Aregular
service and maintenance schedule should be established to
ensure efficient and safe operation of the unit. See System
Maintenanceonpage5.
OPERATING INSTRUCTIONS
Thermostatstylesvary.SomemodelsmaynotincludetheAUTO
mode and others will have the AUTO in place of the HEAT
andCOOL.Othersmayincludeallthree.Pleaserefertothe
thermostat’s User manual for detailed programming instructions.
Thethermostatshouldbemountedabout5feetabovetheoor
on an inside wall and not on an outside wall or other location
where its operation may be adversely affected by radiant heat
from fireplaces, sunlight, or lighting fixtures, and convective heat
from warm air registers or electrical appliances.
CoolingOperation(1or2StageOperation)
1.SetthethermostatsystemmodetoCOOLandthethermostat
fanmodetoAUTO.SeeFigure1.
2. Set the thermostat temperature selector to the desired
temperature level. The outdoor fan, compressor, and
indoor blower will all cycle on and off to maintain the indoor
temperature at the desired cooling level.
For2-StageModelsOnly:If Stage 1 cool does not satisfy the
thermostatdemand,stage2coolwillenergize.Theoutdoor
compressor and indoor blower will ramp to high speed.
NOTE: If the temperature level is re-adjusted, or the system
mode is reset, the fan and compressor in the outdoor unit
maynotstartimmediately.Theremaybeaprotectivetimer
circuit in the thermostat which holds the compressor and
theoutdoorfanoffforapproximately5minutesfollowinga
previous operation or the interruption of the main electrical
power.
HeatingOperation(1or2StageOperation)
1.SetthethermostatsystemmodetoHeatandthethermostat
fanmodetoAUTO.SeeFigure1.
2. Set the thermostat temperature selector to the desired
temperaturelevel.Theindoorblowerandgasheatmodule
will cycle on and off to maintain the indoor temperature at
the desired heating level.
For2-StageModelsOnly:If Stage 1 heat does not satisfy the
thermostatdemand,stage2heatwillenergize.Theinducer
motor and indoor blower will ramp to high speed.
Figure1.DigitalThermostat
FAN
MODE
TEMPERATURE
SELECTOR
SYSTEM
MODE
WARNING:
Ifoverheatingoccurs,orthegassupplyfailsto
shutoff,shutoffthegasvalvetotheunitbefore
shuttingofftheelectricalsupply.
SystemShutdown
Setthethermostat system modetoOFF (see Figure1)and
thethermostatfanmodetoAUTO.NOTE:Thesystemwillnot
operate, regardless of the thermostat temperature selector’s
setting.
ContinuousIndoorBlowerOperation
The continuous indoor blower operation is typically used to
circulate the indoor air to equalize a temperature imbalance
due to a solar load, cooking, or fireplace operation.
Set
thethermostatfanmodetoON(seeFigure1).Theindoor
blower will start immediately and will run continually until the fan
switchisresettoAUTO.NOTE:Onsomethermostatmodels
thesettingmaybecalledCONT.
Thecontinuousindoorbloweroperationcanbeobtainedwith
thethermostatsystemswitchsetinanyposition,includingOFF.
GAS HEATING / ELECTRIC COOLING UNITS