14 SEER / 95% AFUE
SINGLE PACKAGE GAS HEATING / ELECTRIC COOLING
R8HE / PPG3HE SERIES
INSTALLATION INSTRUCTIONS
WARNING / AVERTISSEMENT
FIRE OR EXPLOSION HAZARD
•Failureto followsafety warnings exactly
couldresultinseriousinjuryorproperty
damage.
•Installationandservicemustbeperformed
byaqualiedinstaller,serviceagencyor
thegassupplier.
•Do not store or use gasoline or other
ammablevaporsandliquidsinthevicinity
ofthisoranyotherappliance.
WHAT TO DO IF YOU SMELL GAS
•Donottrytolightanyappliance.
•Donottouchanyelectricalswitch;donot
useanyphoneinyourbuilding.
•Leavethebuildingimmediately.
•Immediatelycallyourgassupplierfroma
neighborsphone.Followthegassuppliers
instructions.
•Ifyoucannotreachyourgassupplier,call
theredepartment.
RISQUE D’INCENDIE OU D’ EXPLOSION
•Lenon-respectdesavertissementsdesécurité
pourraitentraînerdesblessuresgraves,lamort
oudesdommagesmatériels.
•L’installationetl’entretiendoiventêtreeffectués
par un installateur qualié, un organisme de
serviceoulefournisseurdegazstaller,service
agencyorthegassupplier.
•Ne pas entreposer ni utiliser de l’essence ni
d’autresvapeursouliquidesinammablesdansle
voisinagedecetappareil,nidetoutautreappareil.
QUE FAIRE S’IL Y A UNE ODEUR DE GAZ
•Nepastenterd’allumeraucunappareil.
•Ne toucher à aucun interrupteur électrique;
n’utiliseraucuntéléphonedanslebâtiment.
•Évacuerl’immeubleimmédiatement.
•Appelerimmédiatementlefournisseurdegazen
employantletéléphoned’unvoisin.Respecterà
lalettrelesinstructionsdufournisseurdegaz.
•Sipersonnenerépond,appelerleservicedes
incendies.
DONOTDESTROY.PLEASEREADCAREFULLY&KEEPINASAFEPLACEFORFUTUREREFERENCE.
HORIZONTAL MOUNT SHOWN
3-PHASE&SINGLEPHASE(REVISIONA)
Vista de página 0
1 2 3 4 5 6 ... 51 52

Resumo do Conteúdo

Página 1 - WARNING / AVERTISSEMENT

14 SEER / 95% AFUESINGLE PACKAGE GAS HEATING / ELECTRIC COOLINGR8HE / PPG3HE SERIESINSTALLATION INSTRUCTIONS WARNING / AVERTISSEMENTFIRE OR EXPLOSION

Página 2 - TABLE OF CONTENTS

10Figure4.RefrigerantServicePorts&Air ConditioningCondensateDrainLocationsHIGH SIDELOW SIDECONDENSATEDRAINSecuringScrewsFigure5.Interna

Página 3

11ELECTRICAL WIRING WARNING:ELECTRICALSHOCK,FIREOREXPLOSION HAZARDFailuretofollowsafetywarningsexactlycouldresultinseriousinjuryorprope

Página 4 - REQUIREMENTS&CODES

12• All208-240voltunitsareshippedfromthefactorywiredfor 240 volt transformer operation. For 208V operation, remove the lead from the transf

Página 5

13HeatAnticipatorVerify if the thermostat being used for the installation has a heat anticipator setting. This function allows the thermostat to anti

Página 6

14air-flow. Verify the selected rise is within the specification shown on the furnace rating label or in the tables.DehumidicationOptionsThe fixed spee

Página 7

15GASSUPPLY&PIPING WARNING:FIRE OR EXPLOSION HAZARD• Failuretofollowsafetywarningsexactlycouldresultinseriousinjuryorpropertydama

Página 8 - GroundLevel

16applied on each joint or union using a small paintbrush. If any bubbling is observed, the connection is not sealed adequately and must be retightene

Página 9

17Table3.ManifoldPressureSetting(inWC)forNaturalGasINPUT(BTUH)GASVALVESETTINGALTITUDE ABOVE SEA LEVELZERO TO 1,9992,00OTO2,999FT3,00OTO3

Página 10 - Securing

18STARTUP&ADJUSTMENTSPre-StartCheckList√ Verify the unit is level and allows evaporator condensate to drain.√ Verify heat exchanger condensa

Página 11 - AVERTISSEMENT:

191. Turn ON the manual gas valve, located on the outside of the unit to the ON position.2. Check all gas connections for leaks with a soap and water

Página 12 - % Voltage Imbalance

2TABLE OF CONTENTSIMPORTANT SAFETY INFORMATION... 3REQUIREMENTS&CODES...

Página 13 - Toavoidpersonalinjury

20unit data label. To determine the firing rate, follow the stepsbelow:1. Obtain the gas heating value (HHV) from the gas supplier.2. Shut off all oth

Página 14 - CAUTION:

213. Set the thermostat above room temperature and verify the units operating sequence (page 21). NOTE: The over-temperature limit control should turn

Página 15

22not close within 12 seconds, the control will display a Pressure Switch Open with Inducer On Fault. If the hall effect sensor switch does not close

Página 16

23BlockedVent/CondensateDisposalShutDownThe pressure switch is constantly monitored throughout the ignition cycle. After normal operation is est

Página 17

24local dealer about the availability of maintenance contracts. Routinemaintenanceshouldincludethefollowing: CAUTION:The unit should never be

Página 18

25CleaningofBurnersIf the burners must be cleaned, follow the steps below.1. Shut off the gas supply to the unit either at the meter or at a manual

Página 19

26FIGURES&TABLES2513.50161213.3116CGA3/4" NPTFEMALE DRAINCONNECTORBDOWNFLOWSUPPLY DUCTOPENINGDOWNFLOWRETURN DUCTOPENING23.5045.7513.501247.

Página 20 - Operation

27MODELNUMBERR8HE / PPG3HEUNITWEIGHTSHIPPINGWEIGHTCENTER OF GRAVITY UNITDIMENSIONS(INCHES)A BHEIGHT WITHBASE RAILSHEIGHT WITHOUTBASE RAILSLENGTH WID

Página 21

28AirowInformationTable8.CoolingAirowSettingsSWITCHSETTINGRECOMMENDEDAIRFLOW(CFM)SWITCHSETTINGRECOMMENDEDAIRFLOW(CFM)5 6 7 85 6 7 80 0 0 02TO

Página 22

29R8HE/PPG3HE-X24K060XA/-X30K060XA60,000BTUH,30”CABINET,11”X8”BLOWERW-3/4HPECMMOTOR230 VOLT OPERATIONSWITCHSETTINGS0.20 0.30 0.40 0.50

Página 23

3IMPORTANT SAFETY INFORMATIONPlease read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special

Página 24

30R8HE/PPG3HE-X36*080(X,XA)80,000BTUH,30”CABINET,11”X8”BLOWERW-1HPECMMOTOR230 VOLT OPERATIONSWITCHSETTINGS0.20 0.30 0.40 0.50 0.60 0.70

Página 25

31Table12.BlowerPerformance-3.5TonR8HE/PPG3HE-X42K080XA80,000BTUH,34”CABINET,11”X10”BLOWERW-1HPECMMOTOR230 VOLT OPERATIONSWITCH SET

Página 26 - FIGURES&TABLES

32R8HE-X48*096(X,XA)&R8HE-X60*096(X,XA)96,000BTUH,38”-42”CABINET,11”X10”BLOWERW-1HPECMMOTOR230 VOLT OPERATIONSWITCH SETTINGS0.20 0

Página 27 - (DOWNFLOW APPLICATION)

33GasInformationTable14.GasPipeCapacitiesCAPACITYOFBLACKIRONGASPIPE(CU.FT.PERHOUR)FORNATURALGAS(SPECIFICGRAVITY-0.60)NOMINAL PIPED

Página 28 - AirowInformation

34Figure9.GasValveLabelA. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do

Página 29

35Table16.ElectricalData.SINGLE PHASE MODELSMODELNUMBERR8HE / PPG3HEHEATINGINPUT(BTUH)INDUCERMOTORNOMINALELECTRICALSUPPLY VOLTAGERANGECOMPRESSORFAN

Página 30

36GREENREDSTATUSNOT USEDTEST PORTBLOWER MOTORRCY1TWINDEHUMW1EXPANSIONPORTCOOLHEATFAN SPEED1 2 345 6 78OFF ONFigure11.FixedSpeedMotorControlBoard

Página 31

37WIRING DIAGRAM208/230 Volt / 1 Phase / 60 Hz2-5 Ton Package 2 Stage Gas/Single Stage Air Conditioner NOTES:1. Couper le courant avant de faire letre

Página 32

38WIRING DIAGRAM208/230 Volt / 3 Phase / 60 Hz3-5 Ton Package 2 Stage Gas/Single Stage Air Conditioner NOTES:FIELD WIRINGLEGEND:LOW VOLTAGEHIGH VOLTAG

Página 33 - Input To Furnace (Btu/hr)

39WIRING DIAGRAM460 Volt / 3 Phase / 60 Hz3-5 Ton Package 2 Stage Gas/Single Stage Air Conditioner NOTES:1. Couper le courant avant de faire letretien

Página 34 - Figure9.GasValveLabel

4diagram before making any electrical connections to the unit. See the unit wiring label or Figure 13 (page 37), Figure 14 (page 38), & Figure 15

Página 35 - ElectricalData

40ChargingCharts26028030032034036038040042044046048050080 85 90 95 100 105 110 115 120Liquid Temperature (F)Liquid Pressure (psig)2 TON CHARGING CHAR

Página 36 - ElectricalDiagrams

4126028030032034036038040042044046048050080 85 90 95 100 105 110 115 120Liquid Temperature (F)Liquid Pressure (psig)3 TON CHARGING CHART60657075Add re

Página 37 - WIRING DIAGRAM

4228030032034036038040042044046048050080 85 90 95 100 105 110 115 120Liquid Temperature (F)Liquid Pressure (psig)4 TON CHARGING CHART520125130Remove r

Página 38

43APPENDIXA-HEATEXCHANGERCONDENSATEDRAIN&VENTKIT (HORIZONTALMOUNTAPPLICATIONS) WARNING:ELECTRICALSHOCK,FIREOR EXPLOSION HAZARDFailur

Página 39

44Preparing the pitAfter pit location has been determined, the condensate drain pit must be prepared for installation of the vertical 2” PVC vent pipe

Página 40 - 2.5 TON CHARGING CHART

45recommended for areas where temperatures are below 200 F for extended periods of time but is also dependent on the final depth of the trench if the f

Página 41 - 3 TON CHARGING CHART

46FROSTLINE 3" 2" - 3" ROCK BASEBELOW 2” PVC PIPE12" - 14"OR GREATER 4" - 6" OR DEEPER BACKFILLROCK/DIRTMIXTURERO

Página 42 - 5 TON CHARGING CHART

47APPENDIXB-HEATEXCHANGERCONDENSATEDRAIN&VENTKIT (ROOFCURBMOUNTAPPLICATIONS) WARNING:ELECTRICALSHOCK,FIREOR EXPLOSION HAZARDFailure

Página 43

48SettingtheUnitIMPORTANT NOTE:Beforehoistingandsettingtheunitinplace,theshortpieceoffactoryinstalleddrainlinelocatednexttotheun

Página 44 - READTHISBEFOREYOUDIG!

49ROOF MOUNTED UNIT(ROOF CURB AND ROOF NOT SHOWN)SpringHose Clamp2” PVC x 22.5 Degree Elbow& 1/4” Mesh Screen1/2” ID x 84”Drain HoseFlexible Insul

Página 45 - Preparing the Trench

5GENERAL INFORMATIONThis Single Package Gas Heating / Electric Cooling Unit is designed for outdoor rooftop or ground level slab installations and can

Página 48

Specifications & illustrations subject to change without notice or incurring obligations (07/14).709726A (Replaces 7097260)INSTALLATION / PERFORMAN

Página 49 - ROOF MOUNTED UNIT

6 WARNING:Combustible air must not be drawn from acontaminatedatmosphere.Excessiveexposureto contaminated combustion air will result

Página 50

7CIRCULATING AIR SUPPLY WARNING:Productsofcombustionmustnotbeallowedtoenterthereturnairductworkorthecirculatingairsupply.Failureto

Página 51

8ClearancestoCombustibleMaterialsThese units are certified as combination heating and cooling equipment for outdoor rooftop or ground level installa

Página 52 - ATTENTION INSTALLERS:

9• Securementofthedrainlinetotheinsidesurfaceofthe roof curb is acceptable and should be made in the wood nailer area (top 3.5”) to avoid p