Figure 11. Heater Assembly: Model Linear 60-S40, 80-S40, 100-S40, 125-S40 and 150-S40.
G
F
G G
H
S S
COUPLER
*(HIGH TEMP COUPLER
MODEL 125/150 )
BURNER
END
CAPS
(OPTIONAL)
6"
4"
41'6½" NOMINAL OVERALL ASSEMBLED LENGTH
END
CAPS
(OPTIONAL)
DISTANCE BETWEEN
SUSPENSION POINTS
NO TO EXCEED 12'
10' 3" REFLECTORS
TYPICAL OF 4
6" REFLECTOR
OVERLAP
G
F
3" REFLECTOR
OVERLAP
BURNER INSERT
(SEE DETAIL)
NAT GAS ONLY
6" REFLECTOR
OVERLAP
FIRST SUSPENSION POINT TUBE STRAP
DETAIL
TUBE & REFLECTOR SUSPENSION BRACKET
DETAIL
DETAIL
SLIDING REFLECTOR BRACKET
DETAIL
FIXED REFLECTOR BRACKET
REFLECTOR
TUBE
STRAP
RADIANT
TUBE
2 x SCREWS TIGHTEN TO
FIX REFLECTOR
2 x SCREWS MIN 1/8" GAP TO
ALLOW REFLECTOR TO SLIDE
SUPPLIED
NUT &
BOLT
BURNER INSERT DETAIL PT. NO. 270489
NOTE: FOR MODELS 80/100 NAT GAS ONLY
H G
SF
STANDARD 4" COUPLER
TUBE
STRAP
RADIANT
TUBE
SUPPLIED
NUT & BOLT
SUSPENSION
BRACKET
REFLECTOR
"A"
VIEW ON "A"
COUPLER COUPLER
C
L
2" MINIMUM
REFLECTOR OVERLAP