Form I-EEDU, P/N 150492 R6, Page 7
FIGURE 4C - Front View of Coupled Furnaces
A
A + 2"
(51mm)
Limit
Control
Limit
Control
Size "A"
75-100 14-5/8" 371mm
125-140 17-3/8" 441mm
170 20-1/8" 512mm
200 22-7/8" 581mm
225 25-5/8" 651mm
250 28-3/8" 721mm
300 33-7/8" 860mm
350 39-3/8" 1000mm
400 44-7/8" 1140mm
FIGURE 4D - Top View of Coupled
Furnaces
(NOTE: Access panel may be in top or
bottom of ductwork.)
Access panel for
limit control service
and observation of
coupled units.
Limit Control
(Discharge Duct)
4.0 Dimensions and Clearances
FIGURE 5 - Model EEDU Dimensions - inches (mm)
4.1 Dimensions
Size A B C D E F G-Nat G-Pro H J K L M
Dimensions- inches
75, 100 35 14-1/4 35-11/16 14-5/8 4-3/8 3-15/16 1/2 1/2 5/8 12-1/2 7-1/4 7-7/16 4-5/8
125, 140 35 17 35-11/16 17-3/8 4-3/8 3-15/16 1/2 1/2 5/8 15-1/4 7-1/4 7-7/16 6
170 35 19-3/4 35-11/16 20-1/8 4-3/8 3-15/16 1/2 1/2 5/8 18 7-1/4 7-7/16 7-3/8
200 35 22-1/2 35-11/16 22-7/8 4-3/8 3-15/16 1/2 1/2 5/8 20-3/4 7-1/4 7-7/16 8-3/4
225 35-3/4 25-1/4 35-11/16 25-5/8 4-3/8 4-15/16 1/2 1/2 1-3/8 23-1/2 7-1/4 7-7/16 10-1/8
250 35-3/4 28 35-11/16 28-3/8 7-1/8 4-15/16 1/2 1/2 1-3/8 26-1/4 7-1/4 7-7/16 11-1/2
300 36 33-1/2 38-1/8 33-7/8 9-7/8 5-15/16 3/4 1/2 1-3/8 31-3/4 9-9/16 7-5/8 13-7/8
350 36 39 38-1/8 39-3/8 12-5/8 5-15/16 3/4 1/2 1-3/8 37-1/4 9-9/16 7-5/8 16-5/8
400 36 44-1/2 38-1/8 44-7/8 15-3/8 5-15/16 3/4 1/2 1-3/8 42-3/4 9-9/16 7-5/8 19-3/8
Dimensions - mm
75, 100 889 362 906 371 111 100 13 13 16 318 184 189 117
125, 140 889 432 906 441 111 100 13 13 16 387 184 189 152
170 889 502 906 511 111 100 13 13 16 457 184 189 187
200 889 572 906 581 111 100 13 13 16 527 184 189 222
225 908 641 906 651 111 125 13 13 35 597 184 189 257
250 908 711 906 721 181 125 13 13 35 667 184 189 292
300 914 851 968 860 251 151 19 13 35 806 243 194 352
350 914 991 968 1000 321 151 19 13 35 946 243 194 422
400 914 1130 968 1140 391 151 19 13 35 1086 243 194 492
Unit must be installed so that clearances are provided for combustion air space, ser-
vice and inspection, and for proper spacing from combustible construction. Clearance
to combustibles is dened as the minimum distance from the heater to a surface or
object that is necessary to ensure that a surface temperature of 90°F above the sur-
rounding ambient temperature is not exceeded. See table on top of page 8.
4.2 Clearances
NOTE: See FIGURES 5
and 7 for illustrations of
service clearances.