Figure 5
Figure 4
• Electrical connections must be in compliance with
all applicable local codes and ordinances, and with
the current revision of the National Electric Code
(ANSI/NFPA 70).
• For Canadian installations the electricalconnections
and grounding shall comply with the current Canadian
Electrical Code (CSA C22.1 and/or local codes).
IMPORTANT NOTE:
Ifreplacinganyoftheoriginalwiressuppliedwiththe
furnace,thereplacementwiremustbecopperwiring
having the same guage, voltage, and temperature
rating.
Figure 5. Condensate Drain & Service Ports
ACCESSORY
ROOF CURB
Figure 4. RoofTopInstallation
Condensate
Drain
High Pressure
Low Pressure
AVERTISSEMENT:
RISQUEDECHOCÉLECTRIQUE,
D’INCENDIE OU D’EXPLOSION
Le non-respect des avertissements de sécurité
pourrait entraîner
unfonctionnementdangereux
de l’appareil,
des blessures graves, la mort ou
des dommages matériels.
Un entretein incorrect pourrait entraîner un
fonctionnementdangereuxdel’appareil,des
blessures graves, la mort ou des dommages
matériels
• Couper toute alimentation électrique au
générateur d’air chaud avant de prodéder
auxtravauxd’entretein.
• Aumomentdel’entretiendescommandes,
étiquetez tous les fils avant de les
débrancher. S’assurer de les raccorder
correctement.
S’assurer que l’appareil fonctionne
adéquatement aprés l’entretien.
WARNING:
ELECTRICAL SHOCK, FIRE OR
EXPLOSION HAZARD
Failuretofollowsafetywarningsexactlycould
result in serious injury or property damage.
Improper servicing could result in dangerous
operation, serious injury, death or property
damage.
• Beforeservicing,disconnectallelectrical
powertofurnace.
• When servicing controls, label all wires
prior to disconnecting. Reconnect wires
correctly.
• Verifyproperoperationafterservicing.
ELECTRICAL WIRINGHorizontal to Downflow Conversion
The unit is shipped ready for horizontal duct connections.
If down flow ducts are required, the unit must be converted
following the steps below for both the supply and return
ducts.
1. Remove both horizontal duct caps.
2. Locate the duct cap inside the duct openings and remove
the screw holding it in place.
3. Lift the cap out of the unit. (Hint: The cap can be pushed
up from the bottom by reaching through the fork slot).
4. Cover the horizontal duct openings with the horizontal
duct caps removed earlier in step 1. The insulation will
be on the indoor side.
5. Fasten the cover with screws to seal.
6. Remove and discard the two wood supports beneath
the unit.
Condensate Drain
Condensate is removed from the unit through the 3/4”
female pipe fitting (Figure 5) located on the front side of
the unit. Install a 2 inch condensate trap in the drain line of
the same size and prime with water. When connecting rigid
drain line, hold the female fitting with a wrench to prevent
twisting. Do not over tighten! Refer to local codes and
restrictions for proper condensate disposal requirements.